Product Description

Why I need it?

 

High relative humidity can cause significant, possibly irreparable damage to sensitive equipment, supplies, and products. To ensure dehydration measures work, humidity indicator cards measure the relative humidity (RH) inside sealed packages to allow immediate visual inspection of whether it has sustained unsafe humidity levels.

 

Why I need choose your product?

 

Existing humidity indicator cards found in the market are impregnated with a chemical called cobalt chloride In the dry state, cobalt chloride is blue in color. After absorbing moisture cobalt chloride changes to pink color. A recent amendment made to the European CEE directive 67-548 pertaining to the Classification, Packaging and Labeling of dangerous materials, has classified cobalt chloride as a carcinogenic material. Improper handling of items containing carcinogen may cause health hazards and environment hazards, thus, goods containing cobalt chloride will not meet EU standards.

Our new range of humidity indicator cards are carcinogen-free and meet EU standards and color change can be blue to pink, yellow to azure, blown to green.

 

Advantage:

 

Reversible

Competitive price

Bright color; high recognition

Meet ROHS, EU standards, SGS

A back film to prevent chemical to reverse to your products  

Using environmentally friendly ink and moisture-sensitive chemical

 

Usage :

 

  •  The humidity indicator spots will change from blue (dry condition) to  pink (humidity condition) as the relative humidity changes in the volume of air surrounding the indicator.

 

  • Relative humidity is indicated at the lavender color.
  • Indicator spots will change within eight hours of being exposed to a change in relative humidity.
  • The humidity indicator spots are reversible, and the pink spots will change back to blue when the volume of air is dried. Humidity indicator cards with pink or lavender spots can be returned to a blue color by placing indicators in a sealed container with 33 grams (1 unit) of desiccant for four hours. However, we do not recommend reversing or using cards that have been exposed to high humidity in excess of 60 percent.
  • The highest humidity indicator spot should be blue before being put into use.
  • The humidity indicator will be at its most accurate at a temperature of 23 degrees Celsius 72 degrees Fahrenheit.
  • Avoid contact with indicator spots. Wash any irritated areas with clean water.

 

 

 

 

  

Features: 

1. A quick, low cost method to quantify relative humidity levels inside sealed packaging.

2. Printed with moisture sensitive spots which respond to various levels of humidity with a visible color change from blue to pink.

3. Help to provide visual proof of the relative humidity level within a given environment.

4. Easy to monitor the interior humidity conditions of the package

5. Easy to see if your desiccant is working well or need to be replaced inside a sealed package or closed space.

6. Available in numerous configurations

7. Are constantly indicate relative humidity as low as 10 percent and as high as 60 percent, depending on the application and needs.

8. All the HICs meet MIL-I-8835.

 

Applications:

Electronics industry

semiconductor

PCB

Precision machinery industry

Optical lens, munitions

Computer, information equipment industry,

Instrument industry, organic materials,

In composite materials, metal materials, etc.

 

Storage

1. Store humidity indicators in original sealed container with desiccant when possible. Before using, verify that indicator spots have not changed color.

2. Replace bad desiccant after three openings of container.

3. Store in dry, cool area.

4. Keep indicators out of direct sunlight.

5. Keep humidity indicators away from water or steam. 

 

 

Why choose us ?

 

  1. OEM manufacturer --- 11 years’ experience of Anti-moisture and Mildew, Anti-static products

An effective product research and design team

Using advanced equipment

Having a complete produce line

Making our service more professional

Strong capacity

 

  1. Quality Assurance

Our company holds ISO 9001:2015; ISO 14001:2015 certification.

Our products comply with JEDEC J-033B, RoHS, MIL-I-8835 certification, SGS.

2. Large Scale Production---Competitive Price

Capacity 40% higher, cost 20% lower than competitors

 

Customized moisture-proof application resolution for you

Payment Terms︰TT/LC
Product Image

blue to pink cobalt free HIC
blue to pink cobalt free HIC

Yellow to Azure cobalt free HIC
Yellow to Azure cobalt free HIC

blown to green cobalt free HIC
blown to green cobalt free HIC

Related Products
Yellow Cobalt-free Humidity Indicator Card for PCB Packaging
Yellow Cobalt-free Humidity Indicator Card for PCB Packaging
US $ 0.1
Molecular Sieve Desiccant
Molecular Sieve Desiccant
US $ 0.002
Montmorillonite Clay Desiccant
Montmorillonite Clay Desiccant
US $ 0.00001
silica gel desiccant
silica gel desiccant
US $ 0.00001




Home  |  Product Catalog  |  News  |  Contact Us  |  Sitemap  |  Mobile Version

Powered by DIYTrade.com  Build your FREE website !
Find Best Price For China Products !